Московский Дистрибьюторский Центр

  • На главную
  • Карта сайта
  • Обратная связь
 
 

Телефон в Москве:

+7 (495) 178-09-19

zakaz@skladmasel.ru

 

Mobil Isopar G

Индустриальная продукция: Углеводородные растворители, изопарафины

Mobil Isopar G, isopar G

PERFORMANCE FLUIDS

Effective: September 01, 2005

Isopar® G

Hydrocarbon Fluid

Specifications

Property

Units

Min values

Max values

Typical values

Test method

(Latest method, unless specified otherwise)

Distillation range - Initial boiling point - 50% - Dry point

°C

153.0 157.0 171.0

163.0 168.0 180.0

161 164 173

ASTM D 86-99

Flash point

°C

41.0

 

42

ASTM D 56

Aromatic content (UV)*

mg/kg

 

100

20

EC-A-A07

Bromine index *

mg/100g

 

50

4

EC-A-B03/ASTMD2710

Colour Saybolt

-

+ 30

 

+ 30

ASTM D 6045

Corrosion (3 hrsat50°C)

-

 

1b

1a

ASTM D 130

Density at 15°C

kg/dm3

0.7440

0.7550

0.748

ISO 12185

Non-volatile matter

g/m3

 

10

1

ASTM D 381

Dielectric constant at 25°C *

-

1.995

2.050

2.013

EC-A-G01

Specific conductivity * at25°C

(Ohm• cm)-1

 

°1.5x10-14

8 x 10-15

EC-A-G01

Sulphur content

mg/kg

 

5.0

<1

ASTM D 4045

 Other properties

Property

Units

Typical values

Test method

(Latest method, unless specified otherwise)

Aniline point

°C

77

ASTMD611

Benzene content (GC)*

mg/kg

<1

EC-A-G03

Evaporation rate (n-BuAc = 100)*

-

24

EC-M-F01

KB value

-

29

ASTMD1133

Refractive index at 20°C

-

1.418

ASTMD1218

Surface tension at 25 °C (Wilhelmy Plate)*

mN/m

23.0

EC-M-F02

Viscosity at 25 °C

mPa.s

0.84

ASTM D 445

Viscosity at 25 °C

mmІ/s

1.13

ASTM D 445

Peroxides

mgO/kg

1

ASTM D 3703

 °Cell constant = 1.5 x10-3

* Value may be determined by ExxonMobil procedures equivalent to industry standard test methods. Applicable sampling and testing methods are subject to change without notice and are available for review on request.

©2005 Exxon Mobil Corporation. To the extent the user is entitled to disclose and distribute this document, the user may forward, distribute, and/or photocopy this copyrighted document only if unaltered and complete, including all of its headers, footers, disclaimers, and other information. You may not copy this document to a Web site. ExxonMobil does not guarantee the typical (or other) values. Analysis may be performed on representative samples and not the actual product shipped. The information in this document relates only to the named product or materials when not in combination with any other product or materials. We based the information on data believed to be reliable on the date compiled, but we do not represent, warrant, or otherwise guarantee, expressly or impliedly, the merchantability, fitness for a particular purpose, suitability, accuracy, reliability, or completeness of this information or the products, materials, or processes described. The user is solely responsible for all determinations regarding any use of material or product and any process in its territories of interest. We expressly disclaim liability for any loss, damage, or injury directly or indirectly suffered or incurred as a result of or related to anyone using or relying on any of the information in this document. There is no endorsement of any product or process, and we expressly disclaim any contrary implication. The terms, "we", "our", "ExxonMobil Chemical", or "ExxonMobil" are used for convenience, and may include any one or more of ExxonMobil Chemical Company, Exxon Mobil Corporation, or any affiliates they directly or indirectly steward. ExxonMobil, The ExxonMobil Emblem, the "Interlocking X" Device, Actrel, Escaid, Exx-Print, Exxsol, Han, Isopar, Nappar, Norpar, Varsol and Solvesso are trademarks of Exxon Mobil Corporation.